About: Resolution improvement in fluorescence and phase optical microscopy   Goto Sponge  NotDistinct  Permalink

An Entity of Type : rdac:C10001, within Data Space : data.idref.fr associated with source document(s)

AttributesValues
type
Thesis advisor
Praeses
Author
dc:subject
  • Fluorescence
  • Microscopie optique
  • Thèses et écrits académiques
  • Résolution (optique)
  • Problèmes inverses
  • Microscopie de fluorescence
  • Résolution
  • Microscopie de phase
  • Éclairement structuré
preferred label
  • Resolution improvement in fluorescence and phase optical microscopy
Language
Subject
dc:title
  • Resolution improvement in fluorescence and phase optical microscopy
Degree granting institution
Opponent
note
  • La microscopie optique est une technique essentielle pour de nombreuses disciplines des sciences expérimentales qui nécessitent des résolutions sans cesse plus petites. Dans ce travail de thèse sont présentés plusieurs travaux pour l'amélioration de la résolution en microscopie de fluorescence et en microscopie tomographique par diffraction (MTD), une récente technique de microscopie de phase. Dans un premier temps, il est montré que déposer l'échantillon sur un miroir permet d'augmenter la résolution axiale en MTD et en microscopie confocale de fluorescence. En microscopie confocale, il faut pour cela mettre en forme le faisceau incident grâce à un modulateur spatial de lumière. En MTD, il suffit d'adapter le programme de reconstruction. La deuxième partie présente des algorithmes pour reconstruire des images haute résolution à partir de mesures en éclairement structuré avec de champs d'illumination inconnus, à la fois en microscopie de fluorescence (algorithme blind-SIM) et en MTD. En microscopie de fluorescence, ces algorithmes permettent de simplifier drastiquement les montages expérimentaux produisant l'éclairement structuré et en MTD, d'obtenir des images d'échantillons à fort indice.
  • Various fields of experimental science are constantly requiring smaller resolution for optical microscopy. In this thesis are presented several works for improving resolution in fluorescence microscopy and in Tomographic Diffraction Microscopy (TDM), an emerging phase microscopy technique. In the first part it is shown that one can improve the axial resolution in depositing the sample on a mirror. In confocal fluorescence microscopy, this is done by shaping the illumination beam with a Spatial Light Modulator. In TDM this is done by adapting the reconstruction method. Then algorithms are proposed for reconstructing high-resolution images from structured illumination measurements with unknown illumination fields, both in fluorescence imaging (blind-SIM algorithm) and in TDM. This allows a dramatical simplification of the experimental set-ups in fluorescence structured illumination and the image reconstruction of high optical index samples in TDM.
dc:type
  • Text
http://iflastandar...bd/elements/P1001
rdaw:P10219
  • 2012
has content type
is primary topic of
is rdam:P30135 of
Faceted Search & Find service v1.13.91 as of Aug 16 2018


Alternative Linked Data Documents: ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of May 14 2019, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (70 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software