About: Development of a portable gamma camera for accurate 3-D localization of radioactive hotspots   Goto Sponge  NotDistinct  Permalink

An Entity of Type : rdac:C10001, within Data Space : data.idref.fr associated with source document(s)

AttributesValues
type
Thesis advisor
Praeses
Author
alternative label
  • Dévelοppement d'une caméra gamma pοrtable pοur la lοcalisatiοn précise en trois dimensiοns de pοints chauds radiοactifs
dc:subject
  • Étalonnage
  • Thèses et écrits académiques
  • Imagerie tridimensionnelle
  • Radioactivité
  • Imagerie par rayonnement gamma diffusé
  • Caméras à scintillations
  • Masques codés
preferred label
  • Development of a portable gamma camera for accurate 3-D localization of radioactive hotspots
Language
Subject
dc:title
  • Development of a portable gamma camera for accurate 3-D localization of radioactive hotspots
Degree granting institution
Opponent
note
  • Le présent travail a pour but le développement d’une caméra gamma à masque codé permettant d’estimer la position tridimensionnelle (3D) des sources radioactives. Cela est d’un intérêt considérable dans le cadre d’un grand nombre d'applications, de la reconstruction de la forme 3D des objets radioactifs aux systèmes de réalité augmentée appliqués à la radioprotection. Les caméras gamma portables actuelles ne fournissent que la position angulaire relative des sources gamma à localiser, c'est-à-dire qu'aucune information métrique concernant les sources n’est disponible, comme par exemple leur distance par rapport à la caméra. Dans cette thèse, nous proposons principalement deux approches permettant d’estimer la position 3D des sources. La première approche consiste à étalonner la caméra gamma avec un capteur de profondeur à lumière structurée. La seconde approche permet d'estimer la distance source-détecteur par une méthode d’imagerie gamma stéréoscopique. Pour aligner géométriquement les images obtenues par la caméra gamma, le capteur de profondeur, et la caméra optique, une procédure d'étalonnage n’utilisant qu’une seule source ponctuelle radioactive a été conçue et mise en œuvre. Les résultats expérimentaux démontrent que les approches proposées permettent d'obtenir une précision inférieure au pixel, tant pour l’erreur de reprojection que pour la superposition des images gamma et optiques. Ces travaux présentent également une analyse quantitative de la précision et de la résolution relatives à l’estimation de la distance source-détecteur. De plus, les résultats obtenus ont validé le choix de la géométrie du modèle sténopé pour les caméras gamma à masque codé.
  • A coded aperture gamma camera for retrieving the three-dimensional (3-D) position of radioactive sources is presented. This is of considerable interest for a wide number of applications, ranging from the reconstruction of the 3-D shape of radioactive objects to augmented reality systems. Current portable γ-cameras only provide the relative angular position of the hotspots within their field of view. That is, they do not provide any metric information concerning the located sources. In this study, we propose two approaches to estimate the distance of the surrounding hotspots, and to autonomously determine if they are occluded by an object. The first consists in combining and accurately calibrating the gamma camera with a structured-light depth sensor. The second approach allows the estimation of the source-detector distance by means of stereo gamma imaging. To geometrically align the images obtained by the gamma, depth, and optical cameras used, a versatile calibration procedure has been designed and carried out. Such procedure uses a calibration phantom intentionally easy to build and inexpensive, allowing the procedure to be performed with only one radioactive point source. Experimental results showed that our calibration procedure yields to sub-pixel accuracy both in the re-projection error and the overlay of radiation and optical images. A quantitative analysis concerning the accuracy and resolution of the retrieved source-detector distance is also provided, along with an insight into the respective most influential factors. Moreover, the results obtained validated the choice of the geometry of the pinhole model for a coded aperture gamma camera.
dc:type
  • Text
http://iflastandar...bd/elements/P1001
rdaw:P10219
  • 2017
has content type
is primary topic of
is rdam:P30135 of
Faceted Search & Find service v1.13.91 as of Aug 16 2018


Alternative Linked Data Documents: ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of May 14 2019, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (70 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2025 OpenLink Software