About: ETUDE D'UN SYSTEME DE TRAJECTOGRAPHIE MICROMEGAS POUR LE SPECTROMETRE DIMUON D'ALICE   Goto Sponge  NotDistinct  Permalink

An Entity of Type : rdac:C10001, within Data Space : data.idref.fr associated with source document(s)

AttributesValues
type
Thesis advisor
Author
dc:subject
  • Physique
  • alice
  • Thèses et écrits académiques
  • Physique des particules elementaires et champs
  • Plasma quark gluon
  • detecteur particule
  • compteur proportionnel
  • detecteur gazeux
  • spectrometre dimuon
preferred label
  • ETUDE D'UN SYSTEME DE TRAJECTOGRAPHIE MICROMEGAS POUR LE SPECTROMETRE DIMUON D'ALICE
Language
Subject
dc:title
  • ETUDE D'UN SYSTEME DE TRAJECTOGRAPHIE MICROMEGAS POUR LE SPECTROMETRE DIMUON D'ALICE
Degree granting institution
note
  • ALICE (A LARGE ION COLLIDER EXPERIMENT) EST LE DISPOSITIF EXPERIMENTAL QUI SERA DEVOLUE A L'ETUDE DES COLLISIONS D'IONS LOURDS ULTRA-RELATIVISTES AUPRES DU LHC (LARGE HADRON COLLIDER) DU CERN POUR 2005. DANS LE CADRE DE LA CONCEPTION DE CE DETECTEUR A SUBATECH, UN PROGRAMME DE R & D A ETE POURSUIVIT SUR LES CHAMBRES DE TRAJECTOGRAPHIE DU SPECTROMETRE DIMUON D'ALICE UTILISANT LES DETECTEURS MICROMEGAS. LE PREMIER OBJECTIF DE CE TRAVAIL A ETE D'ETUDIER LES PERFORMANCES DE CE TYPE DE DETECTEUR A PISTES PUIS DE DEMONTRER LA FAISABILITE DE LEUR INTEGRATION POUR LE SYSTEME DE TRAJECTOGRAPHIE DU SPECTROMETRE. DES SIMULATIONS DU SYSTEME DE TRAJECTOGRAPHIE ONT MONTRE LA NECESSITE DE DISPOSER D'UNE LOCALISATION BIDIMENSIONNELLE INTRINSEQUE, CONDUISANT AU DEVELOPPEMENT DE PISTES RESISTIVES POUR CES DETECTEURS. LES TESTS AU LABORATOIRE ET AUPRES DU PS DU CERN ONT MIS EN EVIDENCE, POUR UN MELANGE AR/CO 2 ET UN GAIN DE 10000, UNE RESOLUTION EN ENERGIE DE 20% ET UNE EFFICACITE DE DETECTION SUPERIEURE A 95%. UNE RESOLUTION SPATIALE DE 43 M DANS LA DIRECTION PERPENDICULAIRE AUX PISTES EST OBTENUE PAR RECONSTRUCTION DU BARYCENTRE DE CHARGES. DANS LE SENS DES PISTES, LE PARTAGE DE CHARGES ENTRE LES DEUX EXTREMITES DES PISTES RESISTIVES CONDUIT A UNE RECONSTRUCTION LINEAIRE DE LA POSITION D'IMPACT. DEPENDANT DU RAPPORT SIGNAL SUR BRUIT, LA RESOLUTION OBTENUE VARIE DE 1,1 MM A 500 M.
dc:type
  • Text
http://iflastandar...bd/elements/P1001
rdaw:P10219
  • 2001
has content type
is primary topic of
is rdam:P30135 of
Faceted Search & Find service v1.13.91 as of Aug 16 2018


Alternative Linked Data Documents: ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of May 14 2019, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (70 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software