This HTML5 document contains 29 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

PrefixNamespace IRI
n20http://www.idref.fr/027229890/
marcrelhttp://id.loc.gov/vocabulary/relators/
dctermshttp://purl.org/dc/terms/
n21http://www.idref.fr/127475966/
n19http://www.idref.fr/137132700/
n14http://www.idref.fr/027253139/
n11http://www.idref.fr/139061916/
dchttp://purl.org/dc/elements/1.1/
rdauhttp://rdaregistry.info/Elements/u/
skoshttp://www.w3.org/2004/02/skos/core#
n18http://lexvo.org/id/iso639-3/
n15http://www.idref.fr/055835384/
n8http://iflastandards.info/ns/isbd/terms/contentform/
rdachttp://rdaregistry.info/Elements/c/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n2http://www.idref.fr/24770573X/
frbrhttp://purl.org/vocab/frbr/core#
n16http://www.idref.fr/139075119/
n23http://rdaregistry.info/termList/RDAContentType/
n24http://www.idref.fr/02778715X/
n7http://iflastandards.info/ns/isbd/elements/
n9http://www.idref.fr/027225194/
rdawhttp://rdaregistry.info/Elements/w/
xsdhhttp://www.w3.org/2001/XMLSchema#
n6http://www.idref.fr/034122575/
n12http://www.idref.fr/092870627/
Subject Item
n2:id
rdf:type
rdac:C10001 frbr:Work
marcrel:ths
n11:id n12:id n16:id
marcrel:aut
n19:id
skos:altLabel
Surfaces analysis by scanning electrochemical microscopy
dc:subject
Chimie des surfaces Microscopie électrochimique à balayage Interfaces solide-liquide Thèses et écrits académiques Électrochimie Liquides ioniques
skos:prefLabel
Analyse de surfaces par imagerie électronique
dcterms:language
n18:fra
dcterms:subject
n6:id n9:id n14:id n15:id n20:id n21:id
dc:title
Analyse de surfaces par imagerie électronique
marcrel:dgg
n24:id
skos:note
With the progressive decrease in the size of electronic devices, scientists were obliged to develop tools capable of analyzing surface reactivity on microscopic level. This marked the birth of SECM (Scanning ElectroChemical Microscopy). This technique, derived from scan probe microscopy (STM, AFM) makes it possible the study a local area based on ultramicroelectrodes properties (UME). The UME and the surface to be analyzed are placed in an electrolyte solution containing a redox mediator. The SECM provides a real \"brush\" chemical that will probe the surface. The first part of this work focused on the study of conducting and insulating surfaces, composed of carbon and silicon respectively, which were functionalized by a stable redox molecule (ferrocene), at an oxidized and reduced state. We then studied more complex systems. We used the SECM method to fellow the biocatalytic formation on a conducting and an insulated surface. In the last part of this thesis, we studied the electrode/ionic liquid interfaces. Ionic liquids are salt liquids at room temperature, mostly used in chemistry as a substitute for conventional solvents. With a theoretical model, we used SECM in transient conditions, to determine the diffusion coefficients of organic molecules in this type of solvent. Le développement de dispositifs électroniques de taille de plus en plus petite a obligé le monde scientifique à se doter d'outils pouvant analyser à l'échelle microscopique la réactivité d'une surface. C'est ainsi qu'est né le SECM (Scanning ElectroChemical Microscopy) ou microscopie électrochimique à balayage. Cette technique, dérivée des microscopies à champ proche (STM, AFM), permet d'observer de façon locale une surface en s'appuyant sur les propriétés des ultramicroélectrodes (UME). L'UME et la surface à analyser sont placées dans une solution électrolytique contenant un médiateur rédox. Le SECM fournit alors un véritable \"pinceau\" chimique qui va sonder la surface. La première partie de ces travaux a été consacrée à l'étude de surfaces de carbone conductrices et de surfaces de silicium isolantes, fonctionnalisées par une molécule rédox (ferrocène), stable à l'état oxydé et à l'état réduit. Nous avons ensuite étudié des systèmes plus complexes. Nous avons suivi pas à pas, à l'aide du SECM, la conception d'un édifice biocatalytique sur une surface conductrice et sur une surface isolante. Dans la dernière partie de cette thèse, nous nous sommes intéressés aux interfaces électrode/liquides ioniques. Les liquides ioniques sont des sels liquides à température ambiante qui sont de plus en plus utilisé en chimie comme substituant aux solvants classiques. A l'aide d'un modèle théorique, nous avons utilisé le SECM en conditions transitoires afin de déterminer de façon originale la valeur des coefficients de diffusion de molécules organiques dans ce type de solvant.
dc:type
Text
n7:P1001
n8:T1009
rdaw:P10219
2009
rdau:P60049
n23:1020